Professionnel kabɔri fault locator manufacturer .

 

Wuhan Huayi Electric Power Technology Co., Ltd ye fɛn dilanko tɔnba ye Sinuwa jamana na, a bɛ ɲinini kɛ ani a bɛ kabɛl fault sɔrɔ. Huayi b’a sinsin yiriwali ni feereli kan a yɛrɛma, ani ka cɛsiriw kɛ walasa ka fɛnw cogoya ɲɛ, ka musakaw dɔgɔya, ani ka baarakɛcogo ɲɛ. A bɛ baara kɛ kosɛbɛ kuran, jiko, petoroli, nɛgɛso, minɛnko, kemikɛli ani baarakɛyɔrɔ wɛrɛw la.

 
 
Mun na anw sugandi .

nafolotigiw ka ko kɛlenw .

Sosiyete in sigira sen kan san 2005, wa a ka baara kɛcogo ka ca ni san tan ye. O ye High-Voltage Testers ka fɛn dilanko fɔlɔw dɔ ye Sinuwa jamana na. An ka fɛn dilannenw bɛ AC/DC hipot sɛgɛsɛgɛlikɛlan, seriyali resonant test system, transformateur tester, relay tester, circuit breaker/switch tester, tulu/SF6 sɛgɛsɛgɛlikɛlan, kabɛl sɛgɛsɛgɛlikɛlan ani kuran minɛn wɛrɛw.

Professionnel Technologie Support .

Aw ye kɛrɛnkɛrɛnnenya la sɛgɛsɛgɛli ni furakɛli la ka tɛmɛ san 18 kan. A yɛrɛ ka ɛntɛrinɛti kalanbagaw. Professional on delivery, installation, debugging ani kalan.

 

 

 

ISO ka seereyaw .

An bɛ ni R&D fɛɛrɛbɔ jɛkulu ye min bɛ baara kɛ kosɛbɛ ani jogoɲumanya kɔlɔsili gɛlɛn walasa ka lakana, tiɲɛni ani baarakɛcogo ɲuman sɔrɔ. A tɛmɛna ISO9001 seereyaw la ani a ye patɔrɔnw ka seereyaw sɔrɔ minnu bɛ bɛn o ma.

Lɛrɛ 24 o kɔfɛ-Fara .

Professional After-Fari baara, ka i janto kiliyanw ka hakilinaw la fɛnw kan; ka furaw di sanga 24 kɔnɔ, ni gɛlɛya dɔ bɛ kiliyanw na; Aw bɛ baara kɛ joona ani ka ɲɛ.

 

TDR Cable Fault Locator

Kablon fili suguya dɔw ɲinini .

 

 

Testeur de phasing voltage .

Voltage phasing tester ye phasing product suguya kura ye, aw ye aw jija ka phase position de fila grids (generateur groupe) ni parallèges kelen ye.

Fille le voltage fase meter sans fil .

TAG-8000 Wireless High Voltage Phase Meter, min bɛ kɛ kuran siraw la, fasa sɛgɛsɛgɛliw la, ani fasa sinsinni sɛgɛsɛgɛliw la substations kan, ni fasa sɛgɛsɛgɛli baara ye, fasa sinsinni sɛgɛsɛgɛli, ani kuran sɛgɛsɛgɛli.

Transmission line fault yɔrɔjan sɛgɛsɛgɛli .

O minɛn in tun bɛ kɛ ka yɔrɔ jateminɛ fili jɔyɔrɔ ni transformateur sumanilen cɛ ni sanfɛla transmisi sira bɛ ciriw walima da wulilenw na.

Dugukolo jukɔrɔla kabɛl fault distance locator .

DGC-3H bɛ sisan diɲɛ "Multi-Times Pulse" fɛɛrɛ, Yɛrɛ{3}}Tɛsɛfɛɛrɛw labɛn ani minɛn min bɛ kɛ ka ɲɛsin kunnafonidilanw ma minnu ka bon ani minnu bɛ fɔ kosɛbɛ.

Kablon ɲɛnama dɔnni detektɛri .

Walasa ka forow dɔnni gɛlɛyaw ɲɛnabɔ ka bɔ kabali caman na ni kabaliba jɔli sigicogo n’a ladonni, DS-V kabɔli ɲɛnama dɔnni detektɛri dilannen don ni bi ɛntɛrinɛti fɛɛrɛw ye.

 

Product paramètre .

 

Kablon fault tester(flash tester) .

Goniyahakɛ

CE10 degere -40 degɛrɛ .

Sumanikɛlan fili .

Kɔrɔbɔli jugu ±1% .

Sumanikɛlan yɔrɔjan .

Max janya tɛ dɔgɔya ka tɛmɛ16km kan .

Kɔrɔbɔli yɔrɔjan (fiyentɔ) .

1-3m

Sample teliya .

25MHz .

Kuranko ni fanga sɔrɔcogo .

AC walima DC kɔnɔna na, a bɛ se ka kɛ; AC 220V±10%,Power Consommation A ma tɛmɛ 10W;DC 6V/7AH kan, fanga tacogo 6W

Aw bɛ pulse width ni amplitude ci masin kɔnɔ .

0.2μs,100-120V;2μs,150-160V

Baarakɛcogo fɛɛrɛ .

Low-Voltage pulse, DC high-Voltage flash test and impact high-Voltage flash test

Display Resolution .

v/50 meter,v i n'a fɔ teliya propagate M/μs .

Display Way .

320×240 LCD ni kɔkanna yeelen .

Girinya

6kg .

Dimension 1000 .

500×300×195mm3 .

 

Pathfinder ani locator .

Tracking yɔrɔ janya .

Cable de local

Yɔrɔ min bɛ kɛ ka mɔgɔw kɛlɛ .

0-5MΩ

Yɔrɔ tiɲɛni .

< ±10cm

suturalen juguman dɔnni .

<3m

Dimension 1000 .

Pathfinder, Locator:470×290×255mm3.

A ka ca a la:630×300×130mm3.

Girinya

Pathfinder, locator:9kg .

Accessoire Case:8kg .

 

 
Nafa minnu bɛ sɔrɔ kabɛl fault ɲinini na .
 
01/

Precision detection: .Fɛnɲɛnɛmako ɲɛtaa bɛ jaabi tigitigiw di, ka dɛmɛ don ka filiw jira k’a sɔrɔ u ma sɛgɛsɛgɛli kunntanw kɛ.

02/

Baarakɛla-Friendly interface:Fault sɔrɔbaga fanba bɛ waso ni kunnafoni jɛlenw ye ani jiralan jɛlenw, o b’a to u bɛ se ka kɛ baarakɛlaw ye seko ni dɔnko hakɛ bɛɛ la.

03/

A bɛ se ka kɛ fɛn min ye:A dilanni nɔgɔmanw ni fɛn minnu ka surun, olu bɛ se ka kɛ sababu ye ka taa ni u ye nɔgɔya la ani ka baara kɛ ni u ye yɔrɔ caman na.

04/

A bɛ se ka muɲu:A dilannen don walasa ka baarakɛcogo gɛlɛnw muɲu, a ka c’a la, o minɛnw bɛ se ka ji, buguri, ani u nɔfɛfɛnw kɛlɛ.

05/

Muɲu-Baarakɛcogo:Ni o minɛn ninnu bɛ filiw dɔn joona, u bɛ dɛmɛ don ka dɔ bɔ baara jɔli ni ladonni musakaw la kosɛbɛ.

06/

Donanw jatebɔ sekow:Mɔdeli caman bɛ se ka kunnafoniw sɛbɛn walasa ka kunnafoni sɔrɔ don nataw la, ka sɛgɛsɛgɛli kɛcogo ɲuman sabati waati kɔnɔ.

 

Fault localisation techniques .
 

Waati-Fɛɛrɛ minnu sinsinnen bɛ:O fɛɛrɛw bɛ tali kɛ waati sumani na taamasiyɛnw na minnu bɛ taa fili ni kɔ la. Fault distance (jatebɔ) bɛ jate ka da signal (taamaʃyɛn) jɛnsɛnni teliya kan kabali kɔnɔ.

 

Waveform sɛgɛsɛgɛli:O fɛɛrɛ in bɛ tali kɛ taamasiyɛn-yɔrɔ-ko-fɔlen sɛgɛsɛgɛli la walasa ka fili yɔrɔ dɔn. Yɛlɛma minnu bɛ kɛ jikuruw cogoya la, i n’a fɔ amplitude, phase ani frequency, olu bɛ se ka fili dɔ sɔrɔli jira.

 

Frequency Domain Analysis:Ni i ye kabali ka frequency jaabi sɛgɛsɛgɛ, filiw bɛ se ka dɔn ani ka sɔrɔ. Impedance changement, reflexions, walima frequency-Effects de dépendantes minnu bɛ sɔrɔ filiw fɛ, olu bɛ se ka dɔn.

 

 
Kablon fili yɔrɔ min bɛ baara kɛ ni a ye .
 

Seko ni dɔnko siratigɛ la .

transmission ani distribution kabɔri breakpoint ani dugukolo fili yɔrɔ.

Communication Network .

Fibre optique walima kuran kabɔri tiɲɛni ani baarakɛcogo tiɲɛni dɔnni.

Nɛgɛso bolifɛnw .

Subway ani sanfɛ-Speed ​​Rail signal cable fault gɛlɛyaw ɲɛnabɔli.

Industriyali ka baara .

Factory ka kuran walima a ka kunnafonidilanw dilancogo teliya la.

 

Accessoire .

 

Nimɔrɔ

Tɔ̀gɔ

Da

Nimɔrɔ

Tɔ̀gɔ

Da

1

Mainframe de flash instrument .

Kelen

12

Probe de a frame .

Fila

2

Flash instrument ka sampling unit .

Kelen

13

Telefɔni minɛbaga .

Kelen

3

Siginiden layini flash instrument .

Kelen

14

Telefɔni minɛbaga ka layini min bɛ ɲɔgɔn sɔrɔ .

Fila

4

Fuse ka kɛ minɛn ye .

Saba

15

sinsinnan .

Kelen

5

Sira Minɛn .

Kelen

16

Kungolodilan .

Kelen

6

Siginiden sira min bɛ sira minɛn kan .

Kelen

17

sirilanw .

Kelen

7

Point Meter .

Kelen

18

Saba-Kore Power Line .

Fila

8

chargeur de point meter .

Kelen

19

Dugukolo kan plɔmu kɛrɛnkɛrɛnnen .

Kelen

9

T Probe .

Kelen

20

A ɲɛfɔli .

Kelen

10

Kalansen dɔ .

Kelen

21

Sɛgɛsɛgɛli rapɔɔri .

Kelen

11

A bɛ kɛ ni fɛn dɔ ye min bɛ se ka kɛ fɛn ye .

Kelen

22

Seereyaw .

Kelen

 

 
Lakanali sariyaw .

Kablon fili ɲinini bɛ kɛ ni kuran kabɔri ɲɛnamaw ye. A nafa ka bon ka tugu lakana kɛcogo ɲumanw na ani ka fɛɛrɛw tigɛ ka aw to baara la ni nin minɛn ninnu ye.

Baarakɛlaw ka kan ka kalan kɛ ka ɲɛsin fault locator minɛnw baaracogo n’u baara ma, o la, lakana sariyaw faamuyali min kɛrɛnkɛrɛnnen don minɛn in ma.

A nafa ka bon kosɛbɛ ka dugukolo ni u danfara ka ɲɛ walasa ka kuran sɔgɔli bali ani ka minɛnw tanga tiɲɛni ma.

Ka tugu izini lakanani sariyaw n’a sariyaw kɔ, o nafa ka bon walasa ka faratiw nɔgɔya ani ka baarakɛlaw lakana minnu bɛ kabɛl fault sɔrɔli baara la.

 

Cogo min na an bɛ se ka jɛɲɔgɔnya kɛ ni an ye .

 

Aw bɛ se ka kuma an fɛ ni ɲininkali dɔw ye fɛnw, baarakɛminɛnw, walima fɛɛrɛtigɛ koɲɛw kan. An bɛna kɛ aw fɛ tuma bɛɛ ani ka aw magow lamɛn.

An ka ladɛrɛsi .

Gaoxin 4nan sira, No.40, Wuhan dugu, Sinuwa

Telefɔni nimɔrɔ .

(+86)-18062012971/WhatsApp:+8618064115448

e-Masaya .

Sales@sinohipot.com/ tina@sinohipot.com

 

pakew ni fɛnw lasecogo .

 

Packing detail:

Aw bɛ a pake ni jiri kɛsu ye, ka fɛnw cicogo wɛrɛw di.

Sarali:

An bɛ sɔn wari sarali waati caman na, i n’a fɔ T/T, Western Union, L/C.

Garanti waati:

Kelen{0}}San garanti, a sigili ani a baara kɛrɛnkɛrɛnnenw.

Lase waati:

An ka fɛn dilannenw fanba bɛ sɔrɔ ani u bɛ se ka lase wari sarali la. A ka c’a la, jiginni waati tɛ tɛmɛ tile 15 kan.

 

productcate-1-1

productcate-1-1

 

An ka seereyaw .

 

 

productcate-1-1

 

FAQ .

J: Ne bɛ se ka komandi kɛ cogo di?

A: Aw bɛ se ka anw sɔrɔ ɛntɛrinɛti kan walima ka ɲininkali dɔ ci an ma. Aw ye aw ka wajibiw ɲɛfɔ ka jɛya cogo bɛɛ la. O la, an bɛ se ka o fɛn di aw ma a siɲɛ fɔlɔ la.

J: N bɛ se ka sɔngɔ sɔrɔ tuma jumɛn?

A: A ka c’a la an bɛ quotation (fɔlikan) kɛ sanga 24 kɔnɔ an ye i ka ɲininkali sɔrɔlen kɔfɛ.

J: I ka komandi hakɛ fitinin ye mun ye, yala i bɛ se ka samplew ci n ma wa?

A: An ka komandi hakɛ fitinin ye 1 set ye, ani sample shipping fee ka kan ka di i ma.

J: Yala aw bɛ ni fɛnw ye minnu bɛ sɔrɔ stock la .

A: An ka tester fanba bɛ stock.Aw bɛ se ka anw sɔrɔ walasa ka a dɔn ni .

J: Yala fɛnw bɛ yen minnu sɛgɛsɛgɛra sani u ka ci wa?

A: An ka fɛn dilannenw bɛ izini sɛgɛsɛgɛli kɛ, wa u bɛ kɛ ni kunnafoniw ye.

J: Yala i bɛna jigitigɛ sɔrɔ wa?

A: Ɔwɔ an tun bɛ se ka jigitigɛ wɛrɛ di ka kɛɲɛ ni i ka komandi hakɛ ye. An bɛ to ka baara kɛ tuma bɛɛ san o san.

J: I ka fɛn dilannenw bɛ taa jamana wɛrɛw la wa?

A: An ka san 10 ni kɔ bɛ taa jamana wɛrɛw la. Aw bɛ se ka kuma an fɛ walasa ka a sɛmɛntiya ni sigida jɛɲɔgɔn dɔ bɛ yen.

J: Bololabaara bɛ kɛ cogo di?

A: A ka c’a la an bɛ da ni da la Express Delivery ,cause a ka nɔgɔn ani ka teliya.

J: Kablon fili ɲinini bɛ baara kɛ cogo di?

A: A bɛ baara kɛ ni sɛgɛsɛgɛli taamasiɲɛw ci ye ka bɔ kabali fɛ ani ka taamasiyɛn jiracogo walima a tigɛcogo sɛgɛsɛgɛ walasa ka filiw sɔrɔ. Nin wale in bɛ tali kɛ surge generator la - min bɛ fɔ kosɛbɛ ko thumper - min bɛ sanfɛ-voltage pulses ci ka bɔ kabali fɛ. Fault yɔrɔ la, o pulses (fɔlikanw) bɛ flashover (flashover) Kɛ, o bɛ mankan mɛnta, walima thump (fɔkan) ani elekitoromagnɛtiki-yɔrɔ Sɔrɔ.

J: Impulse current method ye mun ye ka ɲɛsin kabɛl fault locator ma?

A: Ni impulsion current method ye, surge voltage pulse bɛ bɔ kabali kɔnɔ walasa ka tiɲɛni kɛ fault yɔrɔ la. O tiɲɛni bɛ taama-taama dɔ Bɔ min bɛ Taa ɲɛfɛ ni ka Segin fili yɔrɔ ni kabali laban cɛ.

J: A bɛ se ka kabali fili sugu jumɛnw dɔn?

A: Ka da insulation resistance (RF) kan fault point ani breakdown gap (G) la, kabali filiw bɛ se ka tila ka taa a fɛ ka kɛ da wulilen ye-circuit faults, low-resistance faults, high-Resistance faults, ani flashover faults.

J: Lakanalifɛn jumɛnw bɛ sɔrɔ a kɔnɔ?

A: Built-In Over-Voltage Protection, automatique shutoff, ani lasɔmini jiralanw ye sariya ye min bɛ kɛ ka ɲɛ.

Anw minnu ye kabɛl fault sɔrɔbagaw ni u feerelaw ye kosɛbɛ Sinuwa jamana na, an bɛ jira ni fɛn ɲumanw ye ani sɔngɔw ye minnu bɛ se ka ɲɔgɔn sɔrɔ. Aw ye aw hakili sigi ko aw bɛ kabɛl fault locator sɔngɔ gɛlɛn san Sinuwa jamana na ka bɔ an ka izini na.

Aw ye ɲininkali ci .
Aw ye ɲininkali ci .